To disable battery saver option,kindly follow the below steps :
* Press the BATTERY SAVER button to deactivate the battery saver feature.
* Battery saver LED will turn off indicating that the battery saver mode is disabled.
Note: If the load is less than 40 watts we would sugget to disable battery saver mode.
We recommend the battery saver mode to be enabled if the load is more than 40 watts for
the enchancement of battery life.
This feature helps the UPS to offer consistent runtime during the lifetime of the battery.
It increases battery life up to two times. Runtime of the connected equipment will reduce
when this feature is enabled. Press the BATTERY SAVER button to activate the battery saver
feature. Battery saver LED will illuminate to indicate the UPS is working in the battery
saver mode.
No, we can't set the sensitivity to BX1100CI-IN manually. The BX1100C-IN intelligently adjusts
the sensitivity to tune to the power conditions in your region. There is no user selectable manual
settings.
The no load shutdown feature works when the Battery Saver mode is enabled and the Back-UPS
is in the On Battery mode. The Back-UPS will shutdown if the connected load draws less than
30 W of power for more than 5 minutes. Disable Battery Saver mode if only low power consuming
equipment like ADSL-modem or wi-fi router is connected to the Back-UPS.
The product manual says that it would shutdown if the load is less than 30 W on battery for
5 mins, so 12V 1A is 12W And it means that it would get shoutdown. You have to add more load
(like laptop etc) so that load is more than 30 Watts
It usually depends upon the laptop configuration as well as the processor load on the laptop
at that point of time. High processing drains the backup quickly and low processing can get
you longer backup. Usually backup time varies from 90 to 120 mins.